Power Supply Installation; Overview; Figure 2.17 Power Wiring For Eki-7706 Series - Advantech EKI-7706 Series User Manual

4fe+2g sfp/4ge+2g sfp l2 managed switch
Table of Contents

Advertisement

2.7

Power Supply Installation

2.7.1

Overview

Warning! Power down and disconnect the power cord before servicing or wiring
the switch.
Caution! Do not disconnect modules or cabling unless the power is first switched
off.
The device only supports the voltage outlined in the type plate. Do not
use any other power components except those specifically designated
for the switch device.
Caution! Disconnect the power cord before installation or cable wiring.
The switches can be powered by using the same DC source used to power other
devices. A DC voltage range of 12 to 48 VDC must be applied between the V1+ ter-
minal and the V1- terminal (PW1), see the following illustrations. A Class 2 power
supply is required to maintain a UL panel listing. The chassis ground screw terminal
should be tied to the panel or chassis ground. A redundant power configuration is
supported through a secondary power supply unit to reduce network down time as a
result of power loss.
EKI-7706E-2F, EKI-7706E-2FI, EKI-7706G-2F, EKI-7706G-2FI support 12~48 VDC.
Dual power inputs are supported, which allow you to connect to a backup power
source.
EKI-7706 Series User Manual
Single DC Power
P2 P1
Chassis
GND
(pane)
One DC Supply

Figure 2.17 Power Wiring for EKI-7706 Series

Redundant DC Power
P2 P1
Chassis
GND
(pane)
Dual DC Supplies
19