Data Upload - HIKVISION DS-2DP1618ZIXS-DE User Manual

Table of Contents

Advertisement

3. Set Density Level, including Number of People. Three levels can be configured in total, and the
density increases from level 1 to level 3.
Note:
The number you input means the lower limit of each level. For example, set the Number of People
of Level 1 as 10, Level 2 is 100, and level 3 is 1000. When the number of people in the detection
area is less than 10, the alarm will not be triggered. When the number of people is between 10 and
100, Level 1 alarm will be triggered. When the number of people is between 100 and 1000, Level 2
alarm will be triggered. When the number is above 1000, Level 3 alarm will be triggered.
4. Click
5. Set the Arming Schedule.
1) Check Enable to edit the arming schedule.
2) Select the timeline of a certain day, and drag the left button of the mouse to set the capture
schedule (the start time and end time of the recording task).
3) (Optional) )After you set the scheduled task, you can click
4) Click Save to save the schedule.
6. Set the Linkage Method for People Density detection.
Note:
Before you start, make sure the Data Uploading function has been enabled. Go to Configuration >
People Density > Data Upload to check the Enable Data Uploading checkbox.
The alarm actions will be triggered when the number of people surpass the setting value in
surveillance scene.
 Check Enable to enable the function. Notify Surveillance Center is selectable.
Notify Surveillance Center: Send an exception or alarm signal to remote management software
when an event occurs.
 Click Save to save the settings.

6.5.2 Data Upload

Configure the content and mode when upload to surveillance center.
Steps:
User Manual of PanoVu Series Network Camera
to save the settings.
Configure Data Upload
Figure 6-35
and copy the task to other days.