Sickle Removal - MacDon A30-S Operator's Manual

Pull-type mower conditioners, self-propelled auger headers
Table of Contents

Advertisement

7.8.2

Sickle Removal

WARNING:
Stand to rear of sickle during removal to
reduce risk of injury from cutting edges.
Wear heavy gloves when handling sickle.
a. Stroke sickle to its outer limit.
D
b. Clean area around sickle head and remove nut
and bolt (C).
c. Remove grease zerk from pin (D).
d. Insert screwdriver in groove of pin (D) and pry
up on sickle head pin to free sickle. Pin does
not have to be removed from arm.
e. Pull sickle out.
f.
Cover sickle head to shield bearing from dirt.
Form # 169000