Check The Installation - Plockmatic BK5030 Installation Manual

Hide thumbs Also See for BK5030:
Table of Contents

Advertisement

November 2012

1.7.6 CHECK THE INSTALLATION

1. Switch on the CT5030's power.
Note: CT 5010 / 5030 are identified and installed in the system upon Power On.
To uninstall CT 5010:
- Enter the Service Program Mode
- Select CT 5010 Services
- Set Installed to No
To uninstall CT 5030:
- Enter BK 5030 Servce Components chapter
- Change CT 5030 Installed from Yes to No
2. Refer to the s/w release Document and ensure that the CT s/w is at appropriate level.
3. Run test jobs according to below Table, save all the Boklets
Paper Size
# of sheets
SRA3 /
1
12x18
SRA3 /
1
12x18
SRA4 /
4
9x12
SRA4 /
1
9x12
4. Inspect the output. To correct any issues
Re-run jobs jobs after adjustments and check output Quality.
# of sets
Paper Weight
10
120 gsm
10
220 gsm
10
90 gsm
10
280 gsm
BK5030 chapter 5.5.1.
Size
Image
Offset
SRA3T /
0
12x18T
SRA3T /
0
12x18T
SRA4T /
0
9x12T
SRA4T / 9x12T 0
CT5030 Service manual section 3.
1-95
CHECK INSTALLATION
.
Crease
Crease
SQF
Tool
Offset
Fine
0
Auto
Coarse
0
Auto
Fine
0
Auto
Coarse
0
Auto

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ct5010eCt5030

Table of Contents