Required Tools; Technical Specifications For 48V And 80V Modules Fitted With 3- Or 5-Bay Cabinets - Webasto ProCore Edge 9 Installation, Operation And Maintenance Manual

Hide thumbs Also See for ProCore Edge 9:
Table of Contents

Advertisement

Available languages

Available languages

IOMM

2. Required Tools

Hex key, 4 mm, for the filler screws on the charger top panel
TORX TX30 for the charger top panel
Flathead screwdriver for the terminal screws
TORX TX25 for the DC output power cable panel
3. Technical Specifications for 48V and 80V Modules Fitted
with 3- or 5-Bay Cabinets
Technical Specifications
Model
Number of fitted modules
Max. output power rating
Module type
Nominal input voltage
Cabinet size
Max. input amps (3-phase
480VAC)
Max. CB size
2
Min. fitted AC input
wire size (AWG) per NEC
Max. output amperage:
24-volt battery @ 2.4 V/cell
Max. output amperage:
36-volt battery @ 2.4 V/cell
The number of modules and module type determine the maximum output power rating.
1
The circuit breaker ratings (maximum CB size) should be based on the charger maximum input ratings (input amps) for
2
the number of fitted modules as stated in this section.
Webasto Charging Systems, Inc.
ProCore Edge 9
2
3
6 kW
9 kW
1
48V
9 A
14 A
15 A
20 A
14
12
128 A
192 A
128 A
192 A
ProCore Edge North America
ProCore Edge 9
2
3
6.4 kW
9.6 kW
80V
480 VAC + 10% 3 ph. 50/60Hz
3-bay
9 A
14 A
15 A
20 A
14
12
9 of 68
ProCore Edge 15
4
5
12 kW
15 kW
12.8 kW
48V
5-bay
19 A
24 A
25 A
30 A
10
10
256 A
320 A
256 A
320 A
31241-03-0202
ProCore Edge 15
4
5
16 kW
80V
19 A
24 A
25 A
30 A
10
10

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Procore edge 15

Table of Contents