cONNecTION OF THe POWer UNIT
4.2.5.8 Connection of the temperature monitoring and brake control (X1C)
A switchable KTY84/PTC evaluation is implemented in the COMBIVERT F6. The de-
sired operating mode can be adjusted via the software.If the evaluation is not required,
it must be deactivated via software (=>
X1c
2
4
6
1
3
5
Figure 23:
Terminal block X1C brake control and temperature connection
ATTENTION
1
X1C
2
Figure 24:
Connection of the brake control
PIN
Name
1
BR+
2
BR-
3
reserved
4
reserved
5
TA1
6
TA2
Malfunctions due to incorrect line or laying!
Malfunctions of the control due to capacitive or inductive coupling.
► Do not lay the KTY or PTC line of the motor (also shielded) together
with the control line
► KTY or PTC line inside the motor line is only permissible with double
shielding!
► The input of the temperature detection has basic isolation.
The voltage to the control of a brake is decoupled from the
internal voltage supply. The brake works only with external
voltage supply.
U
=24V
dc
I
2A
max=
F6 Programming
manual).
Description
Brake control / output +
Brake control / output -
―
―
Temperature detection / output +
Temperature detection / output -
57