Brim Leds; Figure 28 Brim Leds; Table 15 Brim Led Functions - Nortel BCM50 Installation And Maintenance Manual

Table of Contents

Advertisement

Table 14 DDIM LED functions (Sheet 2 of 2)
LED
Status
Power
Status
In service
Flashing
Loopback test
On
Receive alarm
On
Receive error
On
Transmit alarm
On
Transmit error
On
All LEDS
Flashing

BRIM LEDs

The BRIM has one additional LED beside each RJ-48C jack. These LEDs are on when the ISDN
line is active.
Figure 28

Figure 28 BRIM LEDs

Power LED
Status LED
Line LEDs
Table 15
describes the functions of the BRIM LEDs.

Table 15 BRIM LED functions

LED
Power
Status
Line
Media bay module LEDs (BCM50 Expansion Units only)
Description
Refer to
"Media bay module LEDs (BCM50 Expansion Units only)"
Refer to
"Media bay module LEDs (BCM50 Expansion Units only)"
The T1, ETSI, or PRI trunks are out of service because a loopback test is
running or the DDIM is initializing.
A continuity loopback test is running.
A problem with the received digital transmission. This half-duplex link does not
work.
A small error as a result of degraded digital transmission. Possible causes are
an ohmic connection, water ingress, or too long a loop.
The DDIM cannot transmit. The DDIM sends an alarm indication signal (AIS) to
the terminating switch. This half-duplex link does not work.
The DDIM is sending a remote alarm indication (RAI) carrier failure alarm (CFA)
to the terminating switch. If the transmit alarm is not on, this error indicates a
far-end or cable problem.
The DDIM is initializing.
shows the location of the LEDs on a BRIM.
Status
Descriptions
Refer to
"Media bay module LEDs (BCM50 Expansion Units only)"
Refer to
"Media bay module LEDs (BCM50 Expansion Units only)"
Shows the status of each line.
79
for details.
for details.
for details.
for details.
BCM50 LED information