Load The Startup Profile Onto The Bcm50; Next Step - Nortel BCM50 Installation And Maintenance Manual

Table of Contents

Advertisement

The Startup Profile is now stored on the USB storage device.

Load the Startup Profile onto the BCM50

To load the Startup Profile:
1
Remove the 25-pair cable from the telephony connector on the BCM50 Main Unit.
2
Disconnect the BCM50 power supply from the BCM50 Main Unit.
3
Insert the USB storage device into the USB port on the BCM50 Main Unit.
If the BCM50 system has a UPS, insert the USB storage device into the USB hub.
4
Connect the power supply to the BCM50.
The BCM50 automatically detects the Startup Profile file and loads the information during the
bootup sequence. When the BCM50 has completed the bootup sequence, the power and status
LEDs are solid green.
5
Remove the USB storage device from the USB port on the BCM50 or the USB hub.
6
Connect the 25-pair cable to the telephony connector on the BCM50 Main Unit.
The Startup Profile is now loaded onto the BCM50 system.

Next step

After you have loaded the Startup Profile, you can connect the data networking cables. Refer to
"Connect the BCM50 system to the LAN and WAN" on page 171
connecting these cables.
Load the Startup Profile onto the BCM50
for information about
Use the Startup Profile to set the basic parameters
153