Connect the power supply using a UPS (optional)

Figure 46 Connect a UPS

If your BCM50 system does not have a UPS, proceed to
UPS" on page
If your BCM50 system has a UPS, perform the following procedure:
1
Mount the UPS within 1.5 meters (5 feet) of the BCM50 system.
The UPS must be close enough to the BCM50 system that the BCM50 power supply can be
connected to both the UPS and the BCM50.
2
Plug one end of the USB cable into the USB port on the UPS.
For information about the location of the ports on the UPS, refer to the UPS documentation.
3
Plug the other end of the USB cable into the USB hub.
4
Plug one end of the second USB cable into the USB hub.
5
Plug the other end of the second USB cable into the USB port on the BCM50 Main Unit.
6
Plug the UPS power cord into the ac power source (wall outlet).
Note: If you are using the Startup Profile for initial configuration of the BCM50
system, make sure that the Startup Profile is saved on your USB storage device
and that the USB storage device is inserted in the USB port of the BCM50 Main
Unit before connecting the power. See
parameters" on page
7
Proceed to
Connect the cables to the BCM50 system
BCM50
USB hub
119.
151.
"Connect the power supply without a UPS" on page
UPS
USB cable
Power supply
"Connect the power supply without a
"Use the Startup Profile to set the basic
119.

Advertisement