Item
No. 5
No. 6
WARNING
No. 7
According to the combination of No. 7 and No. 8, serial communication command mode switches.
No. 8
Turning on one of No. 7 or No. 8 gives command format compatibility with older models.
Standard mode
No. 7: OFF
No. 8: OFF
• Even with the use of LP-F10/F10W mode, there is a difference in communication processing time and I/O operation
timing between older model of LP-F10/LP-F10W and LP-M/LP-S/LP-Z series.
Description
Select the setting method of the remote mode.
ON
Use the input signal of X5 "REMOTE IN" on I/O terminal.
OFF
Use the remote switch on the front of the controller.
• When DIP switch No. 6 is ON, keep DIP switch No. 5 OFF.
Select the remote mode state at powered ON.
ON
Starts up with remote mode ON
OFF
Starts up with remote mode OFF
• When DIP switch No. 5 is ON, keep DIP switch No. 6 OFF.
• If the DIP switch No. 5 or No. 6 are turned on, construct a system for re-pumping
the laser manually as safety protection measures after stop of the laser radiation
due to an interlock or other safety functions.
LP-F10 mode
No. 7: ON
No. 8: OFF
ME-LPM-SSM-10
LP-F10W mode
No. 7: OFF
No. 8: ON
47