„ Test marking, laser check radiation and laser power measurement timing chart
ON
L-GATE OPREQ
OUT
OFF
ON
L-GATE CLREQ
OUT
OFF
ON
L-GATE OP IN
OFF
ON
L-GATE CL IN
OFF
ON
L-GATE CL OUT 1
OFF
ON
L-GATE CL OUT 2
OFF
ON
MARKING OUT
OFF
Item
Time
T1
2 to 510 ms
T2
400 ms or less
T3
1 ms or more
T4
600 ms or less
T5
• If the marking time is shorter than the one-shot output time, marking is output only at the one-shot output time.
In that case, L-GATE CLREQ is output when the marking is completed.
• In case that the L-GATE OP IN does not falls within T2 time, warning E227 may be issued.
Test marking start
T1
T2
T3
T4
T4
T5
Remarks
This signal is turned ON as the one-shot output for confirming the laser gate open/
close timing when test marking, laser check radiation or laser measurement/correction is
performed.
One-shot output time is set on the environment setting screen.
Complete the input of L-GATE OP IN (one-shot signal) within 400 ms after detecting L-GATE
OPREQ output.
The laser gate opening/closing operation completes within 600 ms after T3 falls.
Open the laser gate and start test marking, laser check radiation or laser power
measurement once laser radiation is ready.
ME-LPM-SSM-10
T3
T4
T4
123