2-4-2 Connecting ground and power supply
This section describes how to connect ground and power supply. For the AC power cable, use the attached AC power
cable. The power terminal, protective conductor terminal and frame ground terminal are located on the back side of the unit
as shown below.
LP-M200/M205/M500/M505
Power
Protective conductor
terminal
WARNING
1.
Connect the protective conductor terminal and the frame
ground terminal to the grounding part.
Screw size: M4
Tightening torque: 1.0N·m
• Before connecting the power supply, connect the protective conductor terminal and the frame ground terminal
permanently to the grounding part.
• Install such that the controller housing and the head housing are at the same electric potential.
2.
Loosen two M3 screws of the power terminal casing and remove
it.
3.
Remove the resin cover on the terminal.
Controller
LP-MA00/MA05/MA06
Power
terminal
terminal
• Perform the connection of the Power Terminal Block with power-off state.
There is a risk of electrical shock.
ME-LPM-SSM-10
Protective conductor
terminal
Protective conductor terminal /
Frame ground terminal
Resin cover
Head
Frame ground
terminal: F.G.
Ground
Terminal
59