4-2-3 Air filter
One air filter is placed in the air-cooling area of the controller.
Effect from deterioration
The air filter soiled with dust may reduce the cooling effect of the air-cooling fan. This may cause the performance to
degrade, or failure of the laser marker.
Replacement interval
• There is a broken part, or contamination that cannot be removed by cleaning.
Models of replacement parts
For details of purchasing air filters, please contact our sales agency.
Model
LP-AFT50x5
Steps for cleaning (Daily maintenance) and replacement of air filter
1.
Turn OFF the key switch of the controller, and disconnect the AC power cable.
2.
Loosen the screws of front panel at 2 positions, and
remove them.
3.
Remove the filter.
4.
Clean the filter with neutral detergent and air-dry it.
5.
Attach the dried filter onto the front panel, and tighten it with
the screws.
Tightening torque: 0.3N·m
• Do not attach the filter when it is wet. This may cause the cooling
capacity to degrade, or failure of the laser marker.
Remarks
Set of 5 pieces for the controller
2
ME-LPM-SSM-10
3
133