3.
Laser pumping switch (with white LED): LASER
This is the switch for starting laser pumping.
LED flashes (approx. 20 sec.) in white when the switch is pressed, and it lights up when the laser irradiation becomes
enabled.
4.
Remote switch (with white LED): REMOTE
This is the switch for activating communication control and I/O control. This indicator is lighted-up by pressing this
switch, and is changed into remote mode.
5.
Alarm reset switch (with blue LED): ALARM RESET
This switch is used to reset the system when an alarm generates. LED lights up in blue when an alarm generates.
Release the cause of alarm and press this switch. Alarm can be reset from the input/output terminal, console (optional)
or monitor screen.
6.
Console connector: CONSOLE
This is the connector for console (option).
7.
USB connector B: PC
This is the connector for connecting the attached USB cable. Connect with PC in using Laser Marker NAVI plus.
8.
USB connector A: USB MEDIA
This is the terminal for connecting the USB media or USB mouse.
For registering or saving data in the laser marker, connect a commercially available USB. (USB media with security
features cannot be used.)
You can also connect a USB mouse when setting by using a commercially available monitor.
A USB port is also mounted at the back.
• Do not connect the USB devices other than a USB media or a USB mouse.
9.
Intake vent for controller air cooling
Air inlet for cooling the controller. In this vent the filter is installed.
10. Emergency stop switch *1
This switch is used to forcibly stop the laser pumping.
Push this switch at emergency to stop the laser radiation. Turn the switch to the direction of the arrow to release it.
*1 : Not equipped on LP-Mxxx-LS1 type.