Panasonic LP-M Series Maintenance Manual page 122

Laser marker
Hide thumbs Also See for LP-M Series:
Table of Contents

Advertisement

„ Marking operation timing chart during remote and operating modes
ON
LASER IN
OFF
ON
SHUTTER A IN
OFF
ON
SHUTTER B IN
OFF
ON
READY OUT
OFF
ON
LASER OUT
OFF
ON
TRIG. IN
OFF
ON
MARKING OUT
OFF
ON
MARK END OUT
OFF
ON
L-GATE OP IN
OFF
ON
L-GATE CL IN
OFF
ON
L-GATE CL OUT 1
OFF
ON
L-GATE CL OUT 2
OFF
Item
Time
T1
1 ms or more
T2
T3
600 ms or less
• While the laser gate is closed, the marking ready output is OFF.
122
T2
T1
T3
T3
Remarks
Input one-shot signal of 1 ms or more.
When the laser gate opens, if the marking data generation is not complete, marking ready
output turns ON after the marking data generation is over. It varies depending on the
quantity of data to be marked.
The laser gate opening/closing operation completes within 600 ms after T1 falls.
ME-LPM-SSM-10
T1
T1
T3
T3
T3
T3
T2
T1
T3
T3

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents