Terminal No.
Name / Description
Count-up value correction (SELECT 1 input: ON)
w
Count-down value correction (SELECT 0 input, SELECT 1 input: ON)
e
Input this number when you change the next marking value of the counter function. The counter value
is specified by the step times of count-up or count-down. The step value indicates a value to increase
or decrease per one counting-up or counting-down.
Specify the count-up/count-down with SELECT 0 to 2 input.
Specify the target counter number and step times with D0 to D15 and turn ON set input.
• How to select the counter number:
Select a value from D0 to D7 for the counter number to correct the count-up/count-down value.
The counter No. 0 to 7 is assigned at D0 to D7 respectively.
In case two or more counter numbers are specified, counter values of all the specified counter
numbers are changed.
• How to specify the step times:
Specify a value in D8 to D15 for the step times of count-up or count-down in the binary system.
Indicate values in the binary system as ON/OFF of D8 to D15 with D8 being the lowest digit value.
Example: Count up or count down the counter of the counter number 3 by two steps
• Turn ON D3 which represents the counter number 3.
• Select "0000 0010", which represents the step times 2 in a 8-bit binary system, by specifying ON/
OFF of D8 to D15 as shown in the below table.
D0 to D7: Counter No. 0 to 7
Terminal
Counter No. to reset (SELECT 2 input: ON)
r
Input this number when you restore the present counter value to the initial value for files with the
counter function applied.
Specify the target counter number as D0 to D7 and turn ON the set input.
• How to select the counter number:
Select the counter number to reset from D0 to D7.
The counter No. 0 to 7 is assigned at D0 to D7 respectively.
In case two or more counter numbers are specified, all counters specified are reset.
Example: When the counter No. 0 to 3 are reset.
Turn ON D0, D1, D2, and D3 which represent the counter No. 0, 1, 2, and 3.
D0 to D7: Counter No. 0 to 7
Terminal
Counter Nos. 4 to 7 are the common counters you can use with all the files.
88
Counter No.
D0
0
D1
1
D2
2
D3
3
D4
4
D5
5
D6
6
D7
7
Counter No.
D0
0
D1
1
D2
2
D3
3
D4
4
D5
5
D6
6
D7
7
D8 to D15: Step times
INPUT
Terminal
OFF
D8
OFF
D9
OFF
D10
ON
D11
OFF
D12
OFF
D13
OFF
D14
OFF
D15
INPUT
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ME-LPM-SSM-10
Step times (binary)
INPUT
0
OFF
1
ON
0
OFF
0
OFF
0
OFF
0
OFF
0
OFF
0
OFF

Advertisement