Item
Period
T1
approx. 75 sec.
T2
approx. 20 sec.
T3
T4
10 ms or more
T5
2 to 510 ms
• LP-Mxxx-S type requires the laser gate open / close control to operate the laser marker.
Refer to "3-8 Control of Laser Gate" (P.117) for details.
Remarks
System Starting Time. Change to the remote mode after system start-up.
The time from turning ON the pumping input to completion of pumping.
• When laser pumping is completed:
Time for data creation. It varies depending on the quantity of data to be marked.
• When laser pumping is not completed:
Time for data creation or time for laser pumping, whichever is longer.
Keep the ON status for 10 ms or more.
This is a one-shot output. Set the output time on the environment setting screen. There
is a small margin of error for the setting value.