Auxiliary Output (Non-Safety Output) - Panasonic SF4C Series Instruction Manual

Ultraslim light curtain/type4
Hide thumbs Also See for SF4C Series:
Table of Contents

Advertisement

3-6 Auxiliary Output (Non-safety Output)

This device incorporates the auxiliary output for the non-safety output.
The auxiliary output is incorporated in the emitter.
Auxiliary output
Negative logic of the control
output (OSSD 1 / 2)
<Timing chart>
Light
Light received
received
status
Light
blocked
ON
Control output
(OSSD 1 / 2)
OFF
Auxiliary output
ON
Negative logic
of OSSD
OFF
Do not use the auxiliary output for the purpose of stopping the machine in which the SF4C series is
installed. Failure to do so could result in death or serious injury.
<Reference>
It is possible to change auxiliary outputs by using the handy controller SFC-HC (optional).
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Test input valid
ON
T
30ms or less
Normal mode
Control output (OSSD 1 / 2) status
Light received
Light blocked
OFF
90ms or less
10ms or less
T: SF4C-F□: 9ms or less, SF4C-H□: 7ms or less
Functions
Lockout
ON
ON
55

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents