M306NKT-EPB User's Manual

2.9.6 Connecting to a 100-pin 0.5mm pitch Foot Pattern (Part 2)

Here following is a procedure of connecting to a 100-pin 0.5mm pitch foot pattern on the user system using the M3T-100LCC-
QSD (not included). For details on the M3T-100LCC-QSD (not included), refer to its user's manual.
(1) Attach the TQPACK100SD to the user system.
(2) Attach the TQSOCKET100SDG included with the M3T-100LCC-QSD to the TQPACK100SD.
(3) Attach the M3T-100LCC-QSD to the TQSOCKET100SDG.
(4) Attach the CN2 side of the M30800T-PTC to the J4 side of the M306NKT-EPB.
(5) Attach the M30800T-PTC to the M3T-100LCC-QSD.
Figure 2.14 Connecting to a 100-pin 0.5mm pitch foot pattern (Part 2)
Note on Connecting the User System:
Take care not to attach a converter board in a wrong direction. It may cause a fatal damage to the emulator and
user system.
Note on Connectors of the Converter board:
The connectors of the M30800T-PTC and M3T-100LCC-QSD are guaranteed for only 50 insertion/removal
iterations.
REJ10J0519-0200 Rev.2.00 Oct. 16, 2006
M3T-FLX160-EPB
M306NKT-EPB
CN2 side
(4)
M30800T-PTC
M3T-100LCC-QSD
(not included)
(5)
(3)
TQSOCKET100SDG
(2)
TQPACK100SD
100-pin 0.5mm pitch
(PLQP100KB-A) foot pattern
(1)
No. 1 pin
CAUTION
IMPORTANT
User system
2. Setup