(2) MCU Setting Dialog Box Does Not Appear at Emulator Debugger Startup
Table 5.2 Checkpoints of errors at debugger startup
Error
ERROR 16005:
Communication error occurred.
Data was not sent to the target.
ERROR 16207:
User system cannot be properly built.
ERROR 16211:
PD30F's version is not the same version as the
firmware in the target.
ERROR 16614:
Target MCU is in the reset state.
Reset the user system.
ERROR 16615:
Target MCU cannot be reset.
Reset the user system.
ERROR 16616:
Target is in "HOLD" state.
ERROR 16617:
Target clock is stopped.
ERROR 16618:
Target MCU is not receiving power.
REJ10J0519-0200 Rev.2.00 Oct. 16, 2006
Check all emulator debugger settings, interface cable settings and
switches on the rear of the PC7501 match.
See the user's manuals of PC7501 and emulator debugger.
(1) Download the proper firmware.
See "2.7 Downloading Firmware" (page 28).
(2) Recheck the connection between the PC7501 and this product.
See "2.4 Connecting the PC7501" (page 24).
Download the proper firmware.
See "2.7 Downloading Firmware" (page 28).
(1) Check that the reset pin of the user system is at "H" level.
(2) Check the reset pin of the user system has changed from "L" to "H"
level.
(1) Check that the NMI# pin is at "H" level.
(2) In memory expansion mode or microprocessor mode, check pins
RDY# and HOLD# are at "H" level.
(3) If the reset circuit of the user system has a watchdog timer, disable
the watchdog timer.
(4) Check that power is properly supplied to the user system and that the
user system is properly grounded.
(1) In memory expansion mode or microprocessor mode, check pins
RDY# and HOLD# at "H" level.
(2) The MCU is either in stop mode or wait mode. Either reset the MCU
or cancel the mode with an interrupt.
See MCU specifications.
When the clock is supplied from an external oscillator, check that the
oscillator circuit in the user system is oscillating properly.
Check that power is properly supplied to the user system and that the
user system is properly grounded.