2.8.3 Connecting to a 100-pin 0.65-mm-pitch Foot Pattern (Part 2)

Figure 2.12 shows how to connect a 100-pin 0.65-mm-pitch foot pattern on the user system to the M3T-DUMMY100S (not
included), and here following is its procedure.
For details on the M3T-100LCC-DMS (not included) and M3T-DUMMY100S (not included), refer to each user's manual.
(1) Attach the M3T-DUMMY100S to the user system.
(2) Attach the M3T-100LCC-DMS to the M3T-DUMMY100S.
(3) Attach the CN2 side of the M30800T-PTC to the CN2 side of the FLX160-PRB.
(4) Attach the M30800T-PTC to the M3T-100LCC-DMS.
Figure 2.12 Connecting to a 100-pin 0.65-mm-pitch foot pattern (2/3)
Note on Connecting the User System:
Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the
emulator or user system.
Notes on Connectors of Converter Boards:
The connectors of the M30800T-PTC are guaranteed for only 50 insertion/removal iterations.
The connectors of the M3T-100LCC-DMS and M3T-DUMMY100S are guaranteed for only 20
insertion/removal iterations.
REJ10J0964-0100 Rev.1.00 August 01, 2005
FLX160-PRB
CN2 side
(3)
M30800T-PTC
M3T-100LCC-DMS
(not included)
(4)
On-board evaluation
(2)
M3T-DUMMY100S
(not included)
100-pin 0.65-mm-pitch
(PRQP0100JB-A) foot pattern
(1)
No.1 pin
User system
CAUTION
IMPORTANT
FLASH MCU etc.