(1) Connecting to a 144-pin 0.4-mm-pitch Foot Pattern

Figure 2.9 shows how to connect this product to a 144-pin 0.4-mm-pitch foot pattern on the target
system with the M3T-FLX-144NSE, and here following is its procedure.
(1) Mount the NQPACK144SE included with the M3T-FLX-144NSE to the target system.
For details on the M3T-FLX-144NSE, refer to its user's manual.
(2) Attach the YQPACK144SE included with the M3T-FLX-144NSE to the NQPACK144SE.
(3) Insert the YQ-GUIDE's included with this product to the YQPACK144SE.
(4) Attach the M306K9T2-CPE to the M3T-FLX-144NSE.
(5) Attach the M3T-FLX-144NSE to the YQPACK144SE.
Figure 2.9 Connecting to a 144-pin 0.4-mm-pitch foot pattern
Notes on Connecting the Target System:
• Take care not to attach the converter board in a wrong direction. It may cause a fatal
damage to the compact emulator.
• The small connectors of the M3T-FLX-144NSE are guaranteed for only 50
insertion/removal iterations.