TRIM LIMIT – Note: Drive by wire models only.
The trim limit function will allow the user to configure the ECM to control the
maximum up trim limit function. This trim limit function is only supported if the
ECM has input from the 3 wire trim sensor. This functionality is supported by
model year 2002 and newer ECMs.
Make sure the SELECT FUNCTION menu is displayed on the DDT. Press
the 7 key.
Special Function:
5–FUEL OFFSET
6– ENGINE LOCATION
7–TRIM LIMIT
The TRIM LIMIT screen will appear.
DO YOU WISH TO SET
THE MAXIMUM UP TRIM
LIMIT?
1 = YES 2 = NO
Press the 1 key.
Activate the trim up switch to the desired maximum trim position.
TRIM ENGINE TO
MAXIMUM DESIRED
POSITION.
CONTINUE? 1=YES 2=NO
Press the 1 key
MAXIMUM TRIM LIMIT
SETPOINT WILL NOW
BE STORED IN THE ECM.
CONTINUE? 1=YES 2=NO
Press the 1 key
NEW TRIM LIMIT
UPDATE WAS
SUCCESSFUL.
PRESS 1 TO CONTINUE
Press the 1 key
TURN KEY OFF THEN
BACK TO RUN FOR ECM
TO ACCEPT NEW LIMIT
PRESS MODE TO EXIT
Turning the key off, then back to run, will force the ECM to update the new trim
limit position.
Reference Manual
2.0 Marine Diagnostics
1- Mercury Marine
5 SPECIAL FUNCTIONS
Press the 2 key
Press the 2 key
LIMIT NOT STORED
OPERATION CANCELED
BY USER.
PRESS MODE TO EXIT
LIMIT NOT STORED
OPERATION CANCELED
BY USER.
PRESS MODE TO EXIT
Press
To EXIT