ECM HAS RECEIVED A
PASS RESPONSE
FROM THE RELAY.
PRESS 1 TO CONTINUE
Press 1 key.
DID YOU HEAR
THE RELAY OPEN
AND CLOSE?
1=YES 2=NO
Press 1 key.
Select Load Test:
1-IGNITION
2-FUEL INJECTOR
3-DIRECT INJECTOR
4-OIL PUMP
5-FUEL PUMP
6-HORN
7-MISCELLANEOUS
8-TACHOMETER
9-RELAYS
NOTE: This test will run automatically once the user has entered
relay test.
Press
Available
To EXIT
Reference Manual
2.0 Marine Diagnostics
1-Mercury Marine
RELAY TEST IN
PROGRESS . . . . .
RELAY WILL CYCLE
ON - OFF 5 TIMES
5 SPECIAL FUNCTIONS
ECM HAS RECEIVED A
FAIL RESPONSE
FROM THE RELAY.
PRESS 1 TO CONTINUE
Press 1 key.
DID YOU HEAR
THE RELAY OPEN
AND CLOSE?
1=YES 2=NO
Press 2 key.
REMINDER . . . .
MAKE SURE LANYARD
STOP SWITCH IS NOT
GROUNDED.
CHECK FOR +12 VOLTS
AND ECM CONTROLLED
GROUND TO RELAY
ASSEMBLY.
CHECK HARNESS
CONTINUITY BETWEEN
ECM AND SUSPECT
COMPONENT
REFER TO SERVICE
MANUAL WIRING
SCHEMATIC FOR
INFORMATION