2.0 Marine Diagnostics
OIL PUMP PRIME
NOTE: Priming of Oil Pump should only be needed on pre-delivery,
(new engine installation) if the block has been rebuilt, essentially
any time maintenance to the oiling system is required.
Press the MODE key to return to the SELECT FUNCTION menu.
Make sure that the SELECT FUNCTION menu screen is displayed on
the DDT. Use the
Press the 5 key. The SPECIAL FUNCTIONS screen will appear.
Press the 1 key and follow the instructions on the screen to prime the
electronic oil pump.
PLEASE STOP ENGINE!
PRIME PUMP: KEY ON
PRESS 1 TO START
PRESS 2 TO CANCEL
PRIME IN PROGRESS
OIL INJ CNT = 16
PRESS 2 TO CANCEL
Press the MODE key to return to the SELECT FUNCTION menu.
Press
To EXIT
58
1- Mercury Marine
key to display the additional screens.
Select Function:
1-DATA MONITOR
2-FAULT STATUS
3-SYSTEM INFO
4-HISTORY
5-SPECIAL FUNCTIONS
Select Function:
1-OIL PUMP PRIME
2-CYLINDER MISFIRE
3-OUTPUT LOAD TEST
4-RESET BREAK-IN
5 SPECIAL FUNCTIONS
OIL PUMP
PRIME SUCCESSFUL
OIL INJ CNT = 600
Reference Manual