Settings For The Dip Switch S1; Procedures To Install And Wire Options On A Drive - YASKAWA JOHB-SMP3 Technical Manual

Hide thumbs Also See for JOHB-SMP3:
Table of Contents

Advertisement

WARNING
Fire Hazard. Tighten all terminal screws to the correct tightening torque. Connections that are too loose or too
tight can cause incorrect operation and damage to the drive. Incorrect connections can also cause death or serious injury from
fire.
NOTICE
Damage to Equipment. When you touch the option, make sure that you observe correct electrostatic
discharge (ESD) procedures. If you do not follow procedures, it can cause ESD damage to the drive circuitry.
NOTICE
Damage to Equipment. Do not de-energize the drive while the drive is outputting voltage. Incorrect equipment
sequencing can cause damage to the drive.
NOTICE
Do not operate a drive or connected equipment that has damaged or missing parts. You can cause damage to
the drive and connected equipment.
NOTICE
Use Yaskawa connection cables or recommended cables only. Incorrect cables can cause the drive or option
to function incorrectly.
NOTICE
Damage to Equipment. Correctly connect the connectors. Incorrect connections can cause malfunction or
damage to the equipment.
NOTICE
Damage to Equipment. Make sure that all connections are correct after you install the drive and connecting
peripheral devices. Incorrect connections can cause damage to the option.

Settings for the DIP Switch S1

Use the DIP switch S1 on the option to select the communication protocol.
Use non-conductive tweezers or a tool with a tip width of approximately 0.5 mm (0.02 in) to set DIP switch S1.
Figure 5.1
shows the default settings for the DIP switch S1.
When you use Modbus TCP/IP, set the DIP switch S1 as shown in

Procedures to Install and Wire Options on a Drive

Procedures to install and wire the option are different for different drive models.
Refer to
Table 5.1
to check the procedures to install and wire the option on a drive.
Product Series
A1000
D1000
R1000
U1000
Z1000U
Z1000
GA500
GA700
GA800
YASKAWA SIEP C730600 0IA Modbus TCP/IP Technical Manual
Figure 5.1 Default Settings for DIP Switch S1
Figure 5.2 Settings for the DIP Switch S1
Table 5.1 Procedures to Install and Wire Options on a Drive
Procedures to Install and Wire Options on a Drive
S1
1
O
N
2
3
4
Figure
5.2.
S1
1
O
N
2
3
4
Procedure A
Procedure A
Procedure A
Procedure A
Procedure A
Procedure B
*1
Procedure C
Procedure C
5 Installation Procedure
Page
12
12
12
12
12
13
-
15
15
11

Advertisement

Table of Contents
loading

Table of Contents