IC-KP2-2HB17-2V1D
Technical Specifications
8
Technical Specifications
8.1
Dimensions
8.2
Technical Data
General Data
Number of read/write
heads
UL file number
Displays/Controls
Link/Traffic LED
LEDs 1, 2
LEDs CH1, CH2
PWR/ERR LED
Rotary switch
Electrical Data
Rated operational voltage
Ripple
Current consumption
Power consumption
Galvanic isolation
136.6
15
107
Max. 2
alternatively 1 read/write head and 1 trigger sensor
E87056
Green: connection to the network
Yellow: flashes at the same speed as the data being sent
Status display for read/write heads
Green: Command to read/write head active
Yellow: approx. 1 second if command is executed successfully
Green: reader identified
Red: configuration error
Green: power on
Yellow: system starting
Red: PROFINET bus error
Address setting
20–30 V DC, PELV
10 % at 30 V DC
4 A incl. read/write heads
3.5 W without read/write heads
Basic insulation in accordance with DIN EN 50178, rated
insulation voltage 50 V
eff
95