Setting The Ip Address - Pepperl+Fuchs IC-KP2-2HB17-2V1D Manual

Identcontrol compact unit with ethernet interface
Hide thumbs Also See for IC-KP2-2HB17-2V1D:
Table of Contents

Advertisement

IC-KP2-2HB17-2V1D
Commissioning
The parameters are volatile and non-volatile parameters. Volatile parameters are reset to their
default setting when the system is switched off and on again.
Non-volatile parameters
Parameter
General
Multiplex mode
Read/write head
Trigger mode
Tag type
Ethernet interface
MAC address
DHCP
IP address
Standard gateway
Subnet mask
Assembly inst. Out
Data hold time
Volatile parameters
Parameter
R/W head
Password mode
Password
Configure the R/W system using the system commands described (see chapter 7.11). "99" is
preset as the tag type.
6.4

Setting the IP address

The IP address of the IDENTControl Compact is preset to 169.254.10.12. The way in which the
IP address is modified depends on if you are using a DHCP server.
If you are not using a DHCP server, the IP address is manually assigned: Either select the IP
address using the rotary switch or start the device with the preset IP address and specify the
new IP address on the device website.
If you are using a DHCP server, the server assigns the IP address to the IDENTControl
Compact.
Note!
We recommend using a fixed preset IP address in order to avoid system malfunctions.
Note!
The rotary switch used to select the device address is located on the underside of the
IDENTControl Compact. This rotary switch is no longer accessible once the IDENTControl
Compact is installed.
20
Default setting
Off
Off
99
00:0D:81:xx:xx:xx
Off
169.254.10.12
169.254.254.1
255.255.0.0
100d
50d x 10 ms
Default setting
Off
00000000
Value range
On / off
On / off
00 ... 99
00:0D:81:xx:xx:xx
On / off
yyy.yyy.yyy.yyy
yyy.yyy.yyy.yyy
yyy.yyy.yyy.yyy
100d ... 112d
0d ... 255d x 10 ms
Value range
on / off
00000000 ... FFFFFFFF

Advertisement