Email Function - Pepperl+Fuchs IC-KP2-2HB17-2V1D Manual

Identcontrol compact unit with ethernet interface
Hide thumbs Also See for IC-KP2-2HB17-2V1D:
Table of Contents

Advertisement

IC-KP2-2HB17-2V1D
Commands
Note!
Duplex mode
We recommend the setting auto detect for duplex mode. If you do not select auto detect,
make sure that the same duplex mode is preset for the device communication partner (e.g. the
switch).
7.5.3

Email function

In the Email window, enter the error codes that will prompt the IDENTControl Compact to send
an email. Every response that the IDENTControl Compact sends is allocated a status. The
IDENTControl Compact sends an email when the status and error code of a channel are the
same.
Do not enter an error code for channels that are not connected to a read/write head or are
connected to a trigger sensor. If you intend to enter several error codes, separate them with
commas. Enter a maximum of five error codes per channel.
We recommend the following entries for error codes:
6: Hardware error
7: Internal device error
Note!
Your network will require an SMTP server for you to use the email function.
room 7, line 4, identification system 45
Setting the email function
1. Enter the recipient address in the mail address receiver box.
2. Enter the email address allocated to the device (sender) in the mail address sender box.
The email server may have to recognize the address, depending on the SMTP server.
3. Enter the IP address of the SMTP server in the IP address smtp server box.
4. Enter the error codes for channel 1 or channel 2 in the mail triggered by error codes
boxes. Separate the digits with commas.
5. Enter the subject in the Subject box.
6. Enter any text that you wish to include in the email such as a location or series information in
the Additional email text box. The device adds the channel, the type designation of the
read/write head, and the cause of the error that has occurred to this text.
26

Advertisement

Table of Contents
loading

Table of Contents