VERSION 03/2014
OPERATING MANUAL
6.7.1
GROUNDING THE POWDER COATING SYSTEM
4
1
5
P_02338
1
Only use mains cables with grounding strand!
2
Connect grounding cable with signal ground!
3
Remove all paint from hooks and other hanger parts!
4
Do not wear non-conducting gloves!
5
Wear electrostatically conductive shoes!
6
The fl oor must be electrostatically conductive!
ORDER NUMBER DOC2345334
2
6
PEA-C4XL-S
3
29