Service Specifications
Tandem Drive Case Refill Capacity (each side) ........................................................................ 69,0 liters (18.2 US gal)
Type of oil ............................................................................................................................ See "Fluids and Lubricants"
Oil check interval .................................................................................................................................... each 500 hours
Oil change interval ................................................................................................................................ each 1000 hours
Tandem Drive Case Oil Level Check
Park grader on a level surface. Remove level plug (3) from each tandem case. The oil must be level with the oil level
plug hole. Add oil until it is brought to the proper level. Install all plugs.
Tandem Drive Case Oil Change
Change oil each 1000 hours
Remove the drain plug (2) from each case and drain the oil. Remove the level (3) and filler plugs (1) from each case.
Install the drain plugs. Add specified oil through the filler holes until oil runs out of the oil level hole.
Install and tighten level plugs and filler plugs in each case.
ATTENTION: Dispose used oil in specialized recycling stations.
845b MODELS
2
1
1. FILLER PLUG
2. DRAIN PLUG
3. LEVEL PLUG
4. BREATHER
CHAPTER 6 – LUBRICATION / FILTERS / FLUIDS

TANDEM

4
1
2
3
865b / 885b MODELS
2
1
1. FILLER PLUG
2. DRAIN PLUG
3. LEVEL PLUG
4. BREATHER
4
1
2
3
6-39