6.4.2 Error messages

These messages are meant to warn about device faults.
Message structure:
Byte
bit7
0
F=0
R/R=
1
1
2
3
General error codes
General
Status Code
(in hex)
00h
02h
03h
08h
09h
0Bh
0Ch
0Eh
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
bit6
bit5
bit4
bit3
0
Master MAC-ID
Service Code = 14h
General error code
Specific service error code
Status name
No error
Resource unavailable
Invalid parameter value
Service not supported
Invalid attribute value
Already
in
requested
mode / state
Object state conflict
Attribute not settable
AMT58x-DN DeviceNET®
bit2
bit1
bit0
Description of Status
Service
was
successfully
performed
by
the
specified.
Resources needed for the
object
to
perform
requested
service
unavailable.
A parameter associated with
the request was invalid. This
code
is
used
parameter does not meet the
requirements
of
specification
and/or
requirements defined in an
Application
Specification.
The requested service was
not implemented or was not
defined
for
this
Class/Instance.
Invalid attribute data detected
The object is already in the
mode/state being requested
by the service.
The object cannot perform
the requested service in its
current mode/state.
A request to modify a non-
modifiable
attribute
received.
object
the
were
when
a
this
the
Object
Object
was