Message Data Transfer - Datalogic DeviceNet AMT58 Series Instruction Manual

Hide thumbs Also See for DeviceNet AMT58 Series:
Table of Contents

Advertisement

AMT58x-DN DeviceNET®
Example
Allocation choice =
01h: used to read and write configuration parameters without "I/O
Messages".
03h: activate Polled communication.
61h: activate Cyclic mode communication without ACK.

6.4.4 Message data transfer

These messages are meant to set, read, save or restore
configuration parameters.
Data transfer request:
Byte
bit7
0
F=0
1
R/R=0
2
3
4
5...7
Data transfer response:
Byte
bit7
0
F=0
1
R/R=1
2...7
Service code, Class ID, Instance ID and Attribute ID are meant to set
the type and content of data bytes. They must be specified according
to the "Object dictionary" (see section "6.5 Object dictionary").
34
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
bit6
bit5
bit4
bit3
0
Master MAC-ID
Service Code
Class ID
Instance ID
Attribute ID
Data byte
bit6
bit5
bit4
bit3
0
Master MAC-ID
Service Code
Data byte
bit2
bit1
bit0
bit2
bit1
bit0