RADVision SCOPIA Elite 5200 Series Installation Manual page 30

Hide thumbs Also See for SCOPIA Elite 5200 Series:
Table of Contents

Advertisement

Step 5
Select Locate automatically to instruct the MCU to automatically locate one of the SIP servers
that are present in the domain,
or
Select Specify and enter the following:
Note:
Step 6
To instruct the MCU to register with a SIP registrar and to send service information to the registrar,
perform these steps:
a.
RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5
An IP address or host name of the SIP server, for example <sipserver>.<company>.com.
Figure 4-5
The communication port number of the SIP server address. The default port is 5060.
The transport connection type.
The default is UDP.
The Locate automatically option works only if you have configured a valid IP address at
Configuration > Setup > Network > DNS server1 or DNS server2.
Select Use registrar.
SIP Protocol Section of the Protocols Tab
Figure 4-6
Type List
Performing Initial Configuration of the SCOPIA Elite MCU | 26

Advertisement

Table of Contents
loading

Table of Contents