Cooling system
•
Detach the expansion tank water drain
pipe from the pipe guide connected to
the mounting bracket of the radiators
and remove the pipe retainer clip se-
curing the drain pipe to the cable of the
demand sensor.
•
Remove the cable tie fastening the ca-
ble of the demand sensor to the drain
pipe of the expansion tank.
•
Move the metal clips along the pipe
and disconnect the cooling system
pipe from the pump and the connector
pipe leading to the thermostat valve.
•
Move the metal clip along the pipe and
disconnect the cooling system pipe
from the radiator.