Braking system
If the brake lever still feels "spongy" after completing all checks, it is necessary to bleed the
brakes using this type of procedure.
With the diagnostic tool properly connected, select the function "REAR BLEEDING" in the
section "SETTINGS".
The pump starts running.
While the pump is performing a rotation cycle, operate and release the rear brake pedal until
the message of diagnostic tool cycle completion is received.
This procedure allows the air to circulate and accumulate.
Once the procedure with diagnostic tool is finished, perform again the REGULAR PURGING
to remove the air from the system completely.
Front brake pump
Pos.
Description
1
Screw fastening front brake fluid res-
ervoir to bracket
2
Screw fastening brake fluid reservoir
mounting bracket to handlebar
3
Front brake pump U bolt clamp
4
Front brake lever pin fixing screw
-
Screw used to fasten the brake pipe
cable gland to the lower yoke
BRAK SYS - 450
F
RONT BRAKE MASTER CYLINDER
Type
Quantity
M6
1
M6
1
M6
2
M6
1
M5
1
RSV4 1100 Factory
Torque
7 Nm (5.16 lbf ft)
7 Nm (5.16 lbf ft)
10 Nm (7.38 lbf ft)
10 Nm (7.38 lbf ft)
8 Nm (5.90 lbf ft)
Notes
-
-
-
-
-