Installation; Installation Site And Environment; General - Alpha ESS Storion-SMILE5 Installation, Operation & Maintenance Manual

Energy storage system
Table of Contents

Advertisement

Installation

This manual introduces the basic steps of how to install and set up AlphaESS Storion-SMILE5.
SMILE5-BAT is a sealed component with no access to battery terminals or cell components within the
module.
NOTE: please pay attention for unpacking the battery, otherwise components could be
damaged.
Observe the specified minimum distances to neighboring objects.
The minimum distances ensure that:
There is sufficient heat dissipation,
The storage system outer cover can be opened easily,
There is sufficient space for carrying out maintenance work.
Figure 8 Limit Distance of Installation to Neighboring Objects

2.1 Installation Site and Environment

2.1.1

General

This SMILE5 energy storage system is an indoor system and can only be installed in an indoor
location.
When SMILE5 systems are installed in a room, SMILE5 must not be hampered by the structure of the
building, the furnishings and equipment of the room.
The Storion SMILE5 is naturally ventilated. The location should therefore be clean, dry and adequately
ventilated. The mounting location must allow free access to the unit for installation and maintenance
purposes, and the system panels must not be blocked.
The following location are not allowed for installation:
habitable rooms;
sites where the freezing point is reached, such as garages, carports or other places;
sites with humidity and condensation over 85%;
sites which are salty and where humid air can penetrate;
earthquake areas –additional security measures are required here;
sites that are higher than 3000 meters above the sea level;
sites with explosive atmosphere;
___________________________________________________________________
Installation
Alpha ESS Co., Ltd.
Your Smart Energy
Page 15