CEStronics CES OMEGA FLEX Assembly And Operating Manual page 65

Long shield ils-i
Hide thumbs Also See for CES OMEGA FLEX:
Table of Contents

Advertisement

Steps
1. Hold the Program-Master in the reading field of the locking device for approx. 1 second.
'Delete mode' has been started.
2. Now you can delete any number of locking media successively by holding each locking medium
in the reading field of the locking device for approx. 2 seconds.
The locking medium is deleted.
3. Hold the Program-Master in the reading field of the locking device for approx. 1 second.
'Delete mode' has been terminated.
'Delete mode' is terminated automatically after approx. 5 seconds. The locking media
previously held up to the reading field are deleted from the locking device.
All master media that have been held in the reading field are now no longer authorised to open
this locking device.
Troubleshooting:
Signal
During step 1:
1x
long red
During step 2:
2x
short red
1x
short green
Wide shield replacement handle set ILS-I
Cause
The Program-Master has not yet been authorised for
this locking device.
The locking medium has not been authorised by the
Program-Master being used.
The locking medium was held in the reading field of
the locking device for too short a time. The author-
isation has not been deleted.
11.5   Locking media
Signal
1x
short green
2x
short green
after each
locking medium
1x
long green
Solution
Authorise the Program-Master
Use the Program-Master with
which the locking medium was
authorised.
Hold the locking medium in the
reading field of the locking device
for a longer time.
Page 65 of 83