Steps
1. Hold the Program-Master in the reading field of the locking device for approx. 1
second.
'Authorisation mode' has been started.
2. Now you can authorise any number of locking media successively by holding each
locking medium in the reading field of the locking device for approx. 1 second.
Locking medium is authorised.
3. Hold the Program-Master in the reading field of the locking device for approx. 1
second.
'Authorisation mode' has been terminated.
'Authorisation mode' is terminated automatically after approx. 5 seconds.
The new authorisations remain stored.
All locking media that have been held in the reading field are now authorised to
open this locking device.
A locking medium can only be deleted from a locking device using the same
Program-Master that was used to authorise it.
Troubleshooting:
Signal
After step 1:
1x
long red
After step 2:
1x
long red
Wide shield replacement handle set ILS-I
Cause
The Program-Master could be read but is not
authorised for this locking device.
a) The locking medium has previously been
authorised with a different Program-Master or via
the OMEGA Client software.
b) A master medium was held in the reading field
instead of a locking medium.
11.5   Locking media
Signal
1x
short green
1x
short green
after each locking
medium
1x
long green
Solution
Authorise the Program-Master
Program-Masters cannot be
authorised on V-NET
locking devices.
a) Locking media can only be
authorised with one Program-Master
or via the software.
b) Use a locking medium.
Page 63 of 83