5.2   Details about the office function
5.2.2 Deactivating office mode
Required:
Locking medium that is authorised for the office function
l
Locking device with office function
l
Procedure:
Steps
1. Hold a locking medium authorised for the office function in the reading field of the
locking device.
The locking medium is read and accepted.
2. Continue to hold the locking medium in the reading field of the locking device (for
approx. 2 seconds).
Office mode is deactivated.
Office mode is now deactivated.
Troubleshooting:
Signal
After 2 seconds,
1x
long green
,
1x
short green
are not displayed.
Page 16 of 83
Cause
Office mode cannot be deactivated because
the locking medium is not authorised for the
office function.
Signal
1x
long green
1x
long green
,
1x
short green
Solution
Have your locking medium authorised
for the office function by the system
administrator.
Wide shield replacement handle set ILS-I