11.4 Deleting the System-Master

Deleting the System-Master is designed to restore the security of an OMEGA FLEX system and is not necessary during
normal operation.
Consequences of deleting the System-Master
Deleting the System-Master has the following consequences:
All master media are deleted.
l
All authorisations issued by Program-Masters are deleted.
l
The locking device is reset to normal mode, i.e. all active opening modes (e.g. block mode) are deactivated.
l
...with RF devices the connection between the RF devices is maintained.
l
The following settings are retained after deletion:
Settings implemented with the OMEGA Client (e.g. time profiles, locking device authorisations, etc.) are retained.
l
Opening durations set with the Time-Master are retained.
l
Online devices remain in online mode.
l
Required:
System-Master
l
Procedure:
Steps
1. Hold the System-Master in the reading field of the locking device for approx. 5 seconds.
The System-Master has been deleted.
2. Remove the System-Master from the reading field of the locking device.
The System-Master is now deleted from this locking device.
The locking device automatically uncouples if it was coupled. This ensures that no further access is possible.
Wide shield replacement handle set ILS-I
11.4   Deleting the System-Master
Signal
2x
short green
Page 61 of 83