▶ For a system with liquid cooling, proceed as follows:
▶ Remove the LC kit, see
▶ Remove all memory modules, see
page
274.
Before removing the memory modules, take a note on the
installation slot number for each memory module. Ensure that you
reinstall the memory modules in the slot they were located before
the replacement.
CAUTION
In case of Optane PMem modules are not reinstalled in the right
slots, data can be lost!
▶ Remove all fans, see
▶ Remove all riser modules, see
page
217.
▶ Remove the iRMC microSD card, see
on page
362.
▶ If applicable, remove all M.2 SSDs, see
page
370.
▶ If applicable, remove the Dual microSD 64GB Enterprise, see
the Dual microSD 64GB Enterprise" on page
▶ If applicable, remove the VROC module, see
module" on page
Removing the defective system board
▶ Disconnect all cables from the system board.
RX2530 M6
"Removing the LC kit" on page
"Removing the defective fan module" on page
"Expansion cards and riser cards" on
384.
Upgrade and Maintenance Manual
System board and components
"Removing a memory module" on
"Removing the iRMC microSD card"
"Removing the M.2 SSD" on
377.
"Removing the VROC
300.
192.
"Removing
389