Figure 81: Connecting the cables to the 10x 2.5-inch HDD backplane
▶ Connect the following cables to the HDD backplane:
1 NVMe cable, leading to system board
2 NVMe cable, leading to SAS expander board
3 NVMe cable, leading to system board
4 NVMe cable, leading to SAS expander board
5 NVMe cable, leading to system board
6 Power cable
7 NVMe cable, leading to system board
8 NVMe cable, leading to SAS expander board
9 OOB cable
This example shows NVMe cabling with connections to system board and SAS
expander board.
For the cable plan, see
Concluding steps
▶ If applicable, install the internal RAID riser module, see
internal RAID riser module (option)" on page
▶ Insert all HDD/SSD modules, see
on page
141.
Make sure that you reinstall the HDD/SSD module in the bay it was
located before the HDD backplane replacement.