▶ Push the dummy module into the empty bay until it engages.
Concluding steps
▶ If applicable,
"Switching on the server" on page
▶ If applicable,
"Installing the front cover with lock" on page
7.5.7

Replacing a 2.5-inch PCIe SSD module

Customer Replaceable
Unit (CRU)
Tools:
– Installation frame included: tool-less
– Installation frame excluded: Phillips PH1 / (+) No. 1 screw driver
This procedure is valid, if the PCIe SSD module is controlled by an
onboard controller and the VMD function is enabled in the BIOS. For
more information, see the "Intel Virtual RAID on CPU (Intel VROC) User
Guide".
If the PCIe SSD module is controlled by a RAID controller of the PRAID
EP5xxi/CP5xxi/EP6xxi family, the PCIe SSD module can be installed
during operation (hot-plug), see
modules" on page
CAUTION
All HDD/SSD modules (drives) must be uniquely identified so that they
can be reinstalled in their original bays later. If this is not done, existing
data can be lost.
Preliminary steps
"Locating the defective server" on page
▶ If applicable,
"Removing the front cover with lock" on page
▶ Identify the physical location of the PCIe SSD module, see
SSD configurations" on page
RX2530 M6
Hard disk drive (HDD) / solid state disk (SSD)
"Removing 2.5-inch HDD/SSD
142.
138.
Upgrade and Maintenance Manual
66.
Hardware: 5 minutes
45.
66.
48.
"2.5-inch HDD/