For more information, see the "ServerView Suite Local Service Concept
(LSC)" manual.
Possibilities to get more information about the defective component
– Checking the ServerView System Monitor, available on Windows or Linux
based servers with ServerView agents installed.
For more information, see the "ServerView System Monitor" user
guide.
– Checking the System Event Log (SEL), see
System Event Log (SEL)" on page
– Checking the indicators on the components, see
indicators" on page
– Checking the onboard indicators on the system board using the Indicate
CSS button, see
Using the CSS button on the system board
If the system has been powered off, the onboard indicators guides you to the
defective component.
CAUTION
It is mandatory to disconnect all power cords from the system in order to
use the Indicate CSS functionality.
▶ Shut down and switch off the server.
▶ Disconnect all power cords from the system.
▶ Press the Indicate CSS button to highlight defective components. The
indicator next to the defective component lights up.
RX2530 M6
406.
"Using the CSS button on the system board" on page
Upgrade and Maintenance Manual
Basic hardware procedures
"Viewing and clearing the
89.
"Connectors and
47.
47