2N IP Force 9151101W Installation Manual page 21

Table of Contents

Advertisement

2N Part No. 932061E
2N Part No. 932072E
2N Part No. 932062E
Tip
FAQ:
Electric locks – Difference between locks in 2N IP intercom accesories
BEFO 211211 door signalling, low consumption
12 V / 230 mA
 Regular lock with a built-in contact to indicate whether the door
is open or closed.
BEFO 31211
fail-safe
12 V / 170 mA DC
 The failsafe lock is closed when electricity is switched on. When
electricity is interrupted, the lock is opened.
BEFO 321211
fail-safe, door signalling
12 V / 170 mA
The failsafe lock is closed when electricity is switched on. When
electricity is interrupted, the lock is opened.
It contains a built-in contact to indicate whether the door is open
or closed.
Installation manual 2N® IP Force
 
21 /  118

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents