LAN CommVerter Setup
Table 20: OrIC Config Channels Fields
Field
Host
TCP/IP Port
Device Name
Destination
OrIC Number
Comm. Type
Baud Rate
Data Bits
Parity
Stop Bits
RS-485 Echo
Current Select
Frame Timeout Longest pause in milliseconds between received bits before destination interface interprets the
No Data
Timeout
Note: If the channel configuration is not displayed properly after saving all changes and resetting the device, clear
Page 74
Description
Host TCP/IP Port
Device Name (Ideally should reflect the corresponding destination, i.e. "CL" for Current Loop
destinations)
Channel number between 1-12 (up to 4 per PI)
Communication protocol for the interface Current Loop
• RS-232
• RS-422
• RS-485
• Tokheim
• MPI-Primary
• MPI-Secondary
RS-232 and RS-422 channels are configured on the same PI- channels 1/2 are RS-232 and
channels 3/4 are RS-422
MPI-Primary and -Secondary are used for mechanical PIs, MPI-Secondary is used for channels
3/4 in configurations that enable 4 MPI-C channels.
Communication Interface details
(RS-485 channels only)
(Current Loop channels only) Type of current used by the channel
pause as the end of one message, and interprets further transmissions as a new message (0 = 4
bytes of silence).
The controller checks communication at regular intervals. If no communication is detected within
the timeout interval, the channel will automatically reset. If set to 0, the channel will not reset.
your browser cache and reload the page.
MDE-5411A ForeHB Islander Prime Installation Manual · October 2018
6.3 Setup