Connections; Figure 10 Terminal Block, Power, And Lan Connections (8 Pumps) - Gasboy Islander Prime Instruction And Installation Manual

Table of Contents

Advertisement

4.3 Station Survey
4.3.3.4 Mapping
• Draw a map of the site.
Note: The map methodology and IDs will be used for setup configuration.

4.3.4 Connections

All connections to Islander Prime must be performed to the terminal block and to the Ethernet
port located at the bottom of the Islander Prime pedestal (see
Figure 10: Terminal Block, Power, and LAN Connections (8 Pumps)
The required connections are as follows:
• Dispenser wiring connections
- Pulser (Low Voltage)
- In Use signal (High voltage)
- Valve (High voltage)
• Communications
- RS-232/LAN to TLG console to fuel tank
- RS-485 for Gasboy peripheral device
- Pump communication line (e.g. Current Loop, RS-485, Tokheim, RS-422)
• Mains AC Power and Ground
• LAN connection
• ETH1 for technician and maintenance
• ETH2 secured WAN
MDE-5411A ForeHB Islander Prime Installation Manual · October 2018
Preliminary Guidelines
Figure
10).
Page 25