Figure 53 Current Loop Electronic Pump - Wiring Diagram - Gasboy Islander Prime Instruction And Installation Manual

Table of Contents

Advertisement

Installation
5.5.5.2 Current Loop
The following shows the specific wiring connections between Islander Prime and the Current
Loop pump nozzle, the terminals that differ from the mechanical pump, and the serial
connection between two Current Loop pumps and the terminal block (see
Figure 53: Current Loop Electronic Pump - Wiring Diagram
The Current Loop electronic communication interface is wired according to the following
pinout scheme (see
Table 15:
GND1
CLI_1
CLO_1 CLO_2 n.c.
Page 64
Table
15):
Current Loop Pinouts
GND2
CHSS
GND3
CLI_2
n.c.
CLI_3
CLO_3 CLO_4 n.c.
5.5 Installing Communication Interfaces
GND4
CHSS
CLI_4
n.c.