Event Input Cause Table - Eaton Cutler-Hammer FP-5000 Instructions Manual

Protective relay
Hide thumbs Also See for Cutler-Hammer FP-5000:
Table of Contents

Advertisement

Page 12-8
Table 12.6 Event Operate Cause Table — continued
Cause
Cause Description
55A PF
Apparent Power Factor has operated
55D PF
Displacement Power Factor has operated
Zin Trip
Zone Interlock Trip has operated
PwrAlm
The system alarm for Watt, VA,
or VAR has operated
PwrDmdAlm
The system alarm for Watt demand,
VA demand, or VAR demand has operated
CurDmdAlm
The system alarm for Current
Demand has operated
THD CurAlm
The system alarm for Current Total
Harmonic Distortion has operated
THD VolAlm
The system alarm for Voltage Total
Harmonic Distortion has operated
BrkOpAlm
Breaker Operation Alarm, the number
of breaker operations has exceeded
the programmed limit
AccuCurAlm
Accumulated Current Alarm, the
accumulated interrupted current the
breaker has opened has exceeded the
programmed limit
Any contact input state change can be logged in the Event log if so programmed. Each input can be logged or not logged according to the
program settings (see Section 5). The value given for each event is: Active for an input transition of low to high, or inactive for an input
transition of high to low. Table 12.7 summarizes the contact input causes for an event log.
Table 12.7 Event Input Cause Table
Cause
Cin1State Alt
Cin2State Alt
Cin3State Alt
Cin4State Alt
Cin5State Alt
Cin6State Alt
Cin7State Alt
Cin8State Alt
Cause Description
Contact Input 1 State changed
Contact Input 2 State changed
Contact Input 3 State changed
Contact Input 4 State changed
Contact Input 5 State changed
Contact Input 6 State changed
Contact Input 7 State changed
Contact Input 8 State changed
Value Given
Miscellaneous Trip Status – contains the status flags
that describe all unbalance, frequency, breaker failure,
power factor, and zone interlocking trips
Miscellaneous Trip Status – contains the status flags
that describe all unbalance, frequency, breaker failure,
power factor, and zone interlocking trips
Miscellaneous Trip Status – contains the status flags
that describe all unbalance, frequency, breaker failure,
power factor, and zone interlocking trips
System Alarm Timeout Status – contains
the status flags for all system alarm timeouts
System Alarm Timeout Status – contains the status
flags for all system alarm timeouts
System Alarm Timeout Status – contains the status
flags for all system alarm timeouts
System Alarm Timeout Status – contains the status
flags for all system alarm timeouts
System Alarm Timeout Status – contains the status
flags for all system alarm timeouts
System Alarm Timeout Status – contains the status
flags for all system alarm timeouts
System Alarm Timeout Status – contains the status
flags for all system alarm timouts
Value Given
Active or Inactive
Active or Inactive
Active or Inactive
Active or Inactive
Active or Inactive
Active or Inactive
Active or Inactive
Active or Inactive
IL17569